OBJECTIVE

Intensive glucose management with insulin pump and continuous glucose monitoring therapy in insulin-treated patients with diabetes poses many challenges in all aspects of daily life. Automated insulin delivery (AID) is the ultimate goal of insulin replacement therapy to reduce the burden of managing this condition. Many systems are being tested in the clinical research setting, and one hybrid closed-loop (HCL) system has received Food and Drug Administration (FDA) approval for use in type 1 diabetes patients above the age of 14 years.

METHODS

Literature review and clinical practice experience from the Diabetes and Technology Program at an academic medical center.

RESULTS

This review outlines recent advances in AID systems, focusing on the FDA-approved MiniMed™ 670G HCL system and the real-life experience 1-year post-release in an academic medical center with over 60 patients on this system. The unique challenges of adapting to this new system outside the clinical trial setting are highlighted, and a training protocol designed specifically for the onboarding of first-time users is described.

CONCLUSION

HCL insulin therapy offers several advantages, at the same time posing unique challenges to the user. Systematic training of patients with diabetes transitioning to this system is essential for retention and success of use.

ABBREVIATIONS: AID = automated insulin delivery; CGM = continuous glucose monitoring; FDA = Food and Drug Administration; HbA1c = glycated hemoglobin; HCL = hybrid closed-loop; ICR = insulin to carbohydrate ratio; SAP = sensor augmented pump; T1DM = type 1 diabetes.

Для цитирования: Aleppo Grazia, Webb Kimberly M. INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM.. Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists. 2018. DOI: 10.4158/ep-2018-0097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.