m+Medelevator.RU
← Поиск публикаций
Clinical rehabilitation · 2018

Functional performance and safety of bone-anchored prostheses in persons with a transfemoral or transtibial amputation: a prospective one-year follow-up cohort study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leijendekkers Ruud A, van Hinte Gerben, Frölke Jan Paul, van de Meent Hendrik, Atsma Femke, Nijhuis-van der Sanden Maria Wg, Hoogeboom Thomas J

Аннотация

OBJECTIVES:: (1) To compare level of function, activity, health-related quality of life (HRQoL) and satisfaction in persons with a lower extremity amputation before surgery and 6- and 12-months after implantation of an osseointegration implant and (2) to report adverse events.

DESIGN:: Prospective cohort study.

SETTING:: University medical centre.

SUBJECTS:: A total of 40 consecutive persons (median age: 56 years) who received a transfemoral (31) or transtibial (9) osseointegration implant, between April 2014 and March 2016.

INTERVENTION:: Osseointegration implant surgery followed by a predefined rehabilitation programme.

MAIN MEASURES:: Hip abductor strength, prosthetic use, back pain frequency, postoperative pain, mobility level (Timed-Up and Go (TUG) and wheelchair-boundedness), walking ability (6 minute walking test (6MWT) and walking distance in daily life), HRQoL, satisfaction regarding the prosthesis, and adverse events.

RESULTS:: Strength, prosthetic use, walking distance, HRQoL, and satisfaction level increased significantly at 6- and 12-month follow-up compared to baseline ( P ⩽ 0.002). The TUG showed no change at 6-month follow-up ( P = 0.420) but improved significantly at 12-month follow-up compared to baseline ( P = 0.005). Wheelchair-boundedness decreased from 12/40 participants at baseline to 0 at follow-ups. The 6MWT ( P ⩾ 0.038) and back pain ( P ⩾ 0.437) did not change over time. Stump pain was present in 28/39 and 22/40 of the participants at 6-and 12-month follow-up, respectively. The major adverse events were managed successfully and included three dual-cone breakages and four bone fractures. An uneventful course was completed by 19/31 transfemoral and 4/9 transtibial bone-anchored prostheses users.

CONCLUSION:: Bone-anchored prostheses lead to improved performance and appear to be safe, so they might be considered for persons with socket-related problems.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты