DOI 10.1080/08869634.2022.2056688
Is the quality of occlusal contacts comparable after aligner and fixed orthodontic therapy? A non-randomized cohort comparison using computerized occlusal analysis during 6 months of retention.
Аннотация
OBJECTIVE
Less than ideal contacts have been reported following aligner therapy, but it is considered a transitory problem, spontaneously resolving with the phenomenon of settling.
Methods
Thirty-nine orthodontic patients (14 treated with aligners; 25 with fixed appliances) were evaluated with a digital occlusal analysis system (T-scan™10), assessing Maximum Intercuspation contact simultaneity, symmetry, and relative force distribution at treatment completion and after 3 and 6 months.
RESULTS
No significant differences in occlusal contact quality were found between groups at treatment completion or follow-up. The center of force moved posteriorly and remained stable after 3 months but was located more anteriorly in females (p = 0.01). One-third of patients (both groups combined) had marked contact force asymmetry even after 6 months' retention.
Conclusion
Occlusal contacts were comparable at completion of treatment with aligners or brackets and after 3-6 months of retention. Settling did not improve marked asymmetry in all patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.