DOI 10.3760/cma.j.issn.0253-2727.2019.10.004
[Expression and influencing factors of hepcidin in classical paroxysmal nocturnal hemoglobinuria].
Аннотация
Objective
To investigate the serum expression and influencing factors of hepcidinin patients with classical paroxysmal nocturnal hemoglobinuria (PNH) .
Methods
Retrospective analysis of 36 classical PNH patients from 2016.3 to 2017.3. Serum hepcidin concentration was measured by ELISA method. The relationship between serum hepcidin concentration and erythropoiesis and iron homeostasis parameters was evaluated.
Results
The median serum hepcidin level of 36 classical PNH patients was 32.03 (23.11, 118.48) μg/L, it was significantly lower than of 181.42 (106.80, 250.53) μg/L in 292 normal control subjects (z=-5.107, P<0.001) . The median serum hepcidin of 56.41 (44.60, 95.06) μg/L in PNH patients with normal ferritin was significantly lower than that in normal controls. The median serum hepcidin concentration 23.75 (21.77, 30.35) μg/L in iron deficiency PNH patients was lower than that in the normal ferritin PNH patients. However, the median serum hepcidin level of classical PNH with elevated ferritin patients 336.19 (304.19, 375.08) μg/L was significantly higher not only than that of normal ferritin and iron deficiency PNH ones, but also than that of normal control subjects. Regression analysis showed that serum ferritin, transferrin saturation and serum albumin level were independent influencing factors of serum hepcidin level in patients with classical PNH.
Conclusion
The decreased serum hepcidin level in patients with classical PNH was mainly influenced by iron metabolism factors.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.