MedElevator Войти в исследования
← Поиск публикаций

DOI 10.6009/jjrt.2021_jsrt_77.7.710

Медицинская библиотека · Nihon Hoshasen Gijutsu Gakkai zasshi · 2021

[The Effect of Radiation Protection Education for the Operators' Ocular Lens in Cardiac Catheterization].

Sumi Shinichiro, Yasuda Mitsuyoshi, Ohtani Hiroki, Ishimoto Yohei, Wakabayashi Kohei, Sai Syogo, Sato Hisaya, Kato Kyoichi

СтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to educate operators regarding cardiac catheterization using radiation protection slides prepared for this study and to consider whether or not this radiation protection education contributes to reducing the exposure of the operator's ocular lens. Thermoluminescent dosimeter (TLD) was installed at the outside left, inside left, outside right, and inside right of the X-ray protective eyewear of the operators performing the cardiac catheterization. The exposure dose rate before and after radiation protection education for 3 operators performing cardiac catheterization was compared. The exposure dose ratio was defined by dividing the TLD measurement value, which is the air kerma calculated by the X-ray diagnosis apparatus for the angiography. In other words, this can calculate the ratio of how much the operators are exposed to radiation from the dose of the patient per examination. When comparing the radiation dose ratio obtained from the dosimeter installed on the right outer side before and after education, p-value was <0.05 in the left anterior oblique-cranial and right anterior oblique- cranial, and a significant difference was recognized. The radiation protection education carried out in this study contributes to a reduction in the exposure dose of the operators.

Для цитирования: Sumi Shinichiro, Yasuda Mitsuyoshi, Ohtani Hiroki, Ishimoto Yohei, Wakabayashi Kohei, Sai Syogo, Sato Hisaya, Kato Kyoichi. [The Effect of Radiation Protection Education for the Operators' Ocular Lens in Cardiac Catheterization].. Nihon Hoshasen Gijutsu Gakkai zasshi. 2021. DOI: 10.6009/jjrt.2021_jsrt_77.7.710.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.