Refractive, visual, and safety outcomes of three surgical techniques for aphakia correction.

Redden Liam D, Hoang David, Rangu Nitin, Murphy David A, Ding Kai, Wendelstein Jascha, Riaz Kamran M

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare refractive, visual, and safety outcomes of 3 methods for surgical correction of aphakia: anterior chamber intraocular lens (AC IOL), intrascleral haptic fixation intraocular lens (ISHF-IOL), and Gore-Tex suture fixation of modified eyelet toric intraocular lens (GSF-MET IOL).

SETTING

Tertiary care academic center.

DESIGN

Multisurgeon retrospective case series.

METHODS

Review of 357 eyes undergoing one of the above 3 techniques between 2017 and 2024. Comparative refractive (defocus [spherical equivalent (SE)], astigmatism [refractive cylinder (RefCyl)], and blur [defocus equivalent]), visual acuity (corrected distance visual acuity [CDVA]), and safety outcomes (cystoid macular edema and return to the operating room [ROR] events) were recorded. Owing to concerns about IOL tilting with one of the models, a subgroup analysis was performed on 2 IOL models within the ISHF group. Statistical analyses included descriptive statistics, chi-square tests, 1-way analysis of variance, and 2-sample t testing.

RESULTS

All 3 groups had similar SE ( P = .87), RefCyl ( P = .91), and CDVA in eyes without significant comorbidities ( P = .23). ROR was similar among all groups ( P = .08). Within the ISHF-IOL group, CT Lucia 602 and Sensar AR40 had similar SE and RefCyl ( P = .18 and P = .15, respectively). CDVA was similar in eyes without significant comorbidities for both IOL models ( P = .70). ROR was significantly higher with CT Lucia 602 than with Sensar AR40 ( P = .03).

CONCLUSIONS

All 3 surgical techniques can provide good refractive, visual acuity, and safety outcomes. Within the ISHF-IOL group, the Sensar AR40 had lower ROR rates than the CT Lucia 602, with similar CDVA outcomes.

Для цитирования: Redden Liam D, Hoang David, Rangu Nitin, Murphy David A, Ding Kai, Wendelstein Jascha, Riaz Kamran M. Refractive, visual, and safety outcomes of three surgical techniques for aphakia correction.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001723.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.