MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/acm2.14212

Медицинская библиотека · Journal of applied clinical medical physics · 2023

Cycle-generative adversarial network-based bone suppression imaging for highly accurate markerless motion tracking of lung tumors for cyberknife irradiation therapy.

Mochizuki Zennosuke, Saito Masahide, Suzuki Toshihiro, Mochizuki Koji, Hasegawa Junichi, Nemoto Hikaru, Satani Kenichiro, Takahashi Hiroshi, Onishi Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Lung tumor tracking during stereotactic radiotherapy with the CyberKnife can misrecognize tumor location under conditions where similar patterns exist in the search area. This study aimed to develop a technique for bone signal suppression during kV-x-ray imaging.

METHODS

Paired CT images were created with or without bony structures using a 4D extended cardiac-torso phantom (XCAT phantom) in 56 cases. Subsequently, 3020 2D x-ray images were generated. Images with bone were input into cycle-consistent adversarial network (CycleGAN) and the bone suppressed images on the XCAT phantom (BSIphantom ) were created. They were then compared to images without bone using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). Next, 1000 non-simulated treatment images from real cases were input into the training model, and bone-suppressed images of the patient (BSIpatient ) were created. Zero means normalized cross correlation (ZNCC) by template matching between each of the actual treatment images and BSIpatient were calculated.

RESULTS

BSIphantom values were compared to their paired images without bone of the XCAT phantom test data; SSIM and PSNR were 0.90 ± 0.06 and 24.54 ± 4.48, respectively. It was visually confirmed that only bone was selectively suppressed without significantly affecting tumor visualization. The ZNCC values of the actual treatment images and BSIpatient were 0.763 ± 0.136 and 0.773 ± 0.143, respectively. The BSIpatient showed improved recognition accuracy over the actual treatment images.

CONCLUSIONS

The proposed bone suppression imaging technique based on CycleGAN improves image recognition, making it possible to achieve highly accurate motion tracking irradiation.

Для цитирования: Mochizuki Zennosuke, Saito Masahide, Suzuki Toshihiro, Mochizuki Koji, Hasegawa Junichi, Nemoto Hikaru, Satani Kenichiro, Takahashi Hiroshi, Onishi Hiroshi. Cycle-generative adversarial network-based bone suppression imaging for highly accurate markerless motion tracking of lung tumors for cyberknife irradiation therapy.. Journal of applied clinical medical physics. 2023. DOI: 10.1002/acm2.14212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.