MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0894-7317(99)70189-6

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 1999

Noninvasive assessment of left and right internal mammary artery graft patency with high-frequency transthoracic echocardiography.

De Simone L, Caso P, Severino S, Scherillo M, D'Andrea A, Varricchio A, Violini R, Mininni N

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was (1) to visualize internal mammary artery grafts (IMAG) on coronary artery by transthoracic echocardiography and (2) to assess the patency of the grafts.

METHODS

Twenty-three patients (21 men, 56 +/- 6 years) with previous coronary artery bypass grafting were studied at baseline and after they underwent low-dose dipyridamole infusion. The parameters obtained were systolic (SPV) and diastolic (DPV) peak velocities and their ratio (DPV/SPV); the dipyridamole infusion to baseline ratio of DPV was an index of IMAG blood flow reserve (FR). Two groups of patients were selected at baseline: group A, (n = 12) with a DPV/SPV >1, and group B (n = 11), with a DPV/SPV <1.

RESULTS

The IMAG was identified in all patients. Intraluminal flow signals obtained with pulsed wave Doppler showed a biphasic pattern (1 systolic and 1 diastolic wave). After dipyridamole infusion was administered, flow velocities increased in 11 of 12 patients in group A and in 5 of 11 patients in group B. In group A the DPV/SPV increased from 1.79 +/- 0.47 to 1.8 +/- 0.43 (P = not significant), and the FR was 1.8 +/- 0.4. In group B the DPV/SPV increased from 0. 46 +/- 0.05 to 0.5 +/- 0.09 (P = not significant), and the FR was 1. 3 +/- 0.41. Coronary angiography showed the graft patency in all patients in group A and in 5 patients in group B with increased flow velocity after dipyridamole infusion. In the identification of graft stenosis at baseline, DPV/SPV showed 100% sensibility and 58% specificity, and FR showed 92% sensibility and 84% specificity.

CONCLUSION

Doppler echocardiographic evaluation of the IMAG is a simple noninvasive method to assess the functional impairment of the vessel.

Для цитирования: De Simone L, Caso P, Severino S, Scherillo M, D'Andrea A, Varricchio A, Violini R, Mininni N. Noninvasive assessment of left and right internal mammary artery graft patency with high-frequency transthoracic echocardiography.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 1999. DOI: 10.1016/s0894-7317(99)70189-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.