MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archotol.134.7.757

Медицинская библиотека · Archives of otolaryngology--head & neck surgery · 2008

Multicenter interrater and intrarater reliability in the endoscopic evaluation of velopharyngeal insufficiency.

Sie Kathleen C Y, Starr Jacqueline R, Bloom David C, Cunningham Michael, de Serres Lianne M, Drake Amelia F, Elluru Ravindhra G, Haddad Joseph, Hartnick Christopher, Macarthur Carol, Milczuk Henry A, Muntz Harlan R, Perkins Jonathan A, Senders Craig, Smith Marshall E, Tollefson Travis, Willging Jay Paul, Zdanski Carlton J

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To explore interrater and intrarater reliability (R (inter) and R (intra), respectively) of a standardized scale applied to nasoendoscopic assessment of velopharyngeal (VP) function, across multiple centers.

DESIGN

Multicenter blinded R (inter) and R (intra) study.

SETTING

Eight academic tertiary care centers.

PARTICIPANTS

Sixteen otolaryngologists from 8 centers.

MAIN OUTCOME MEASURES: Raters estimated lateral pharyngeal and palatal movement on nasoendoscopic tapes from 50 different patients. Raters were asked to (1) estimate gap size during phonation and (2) note the presence of the Passavant ridge, a midline palatal notch on the nasal surface of the soft palate, and aberrant pulsations. Primary outcome measures were R (inter) and R (intra) coefficients for estimated gap size, lateral wall, and palatal movement; kappa coefficients for the Passavant ridge, a midline palatal notch on the nasal soft palate, and aberrant pulsations were also calculated.

RESULTS

The R (inter) coefficients were 0.63 for estimated gap size, 0.41 for lateral wall movement, and 0.43 for palate movement; corresponding R (intra) coefficients were 0.86, 0.79, and 0.83, respectively. Interrater kappa values for qualitative features were 0.10 for the Passavant ridge; 0.48 for a notch on the nasal surface of the soft palate, 0.56 for aberrant pulsations, and 0.39 for estimation of gap size.

CONCLUSIONS

In these data, there was good R (intra) and fair R (inter) when using the Golding-Kushner scale for rating VP function based on nasoendoscopy. Estimates of VP gap size demonstrate higher reliability coefficients than total lateral wall, mean palate estimates, and categorical estimate of gap size. The reliability of rating qualitative characteristics (ie, the presence of the Passavant ridge, aberrant pulsations, and notch on the nasal surface of the soft palate) is variable.

Для цитирования: Sie Kathleen C Y, Starr Jacqueline R, Bloom David C, Cunningham Michael, de Serres Lianne M, Drake Amelia F, Elluru Ravindhra G, Haddad Joseph, Hartnick Christopher, Macarthur Carol, Milczuk Henry A, Muntz Harlan R, Perkins Jonathan A, Senders Craig, Smith Marshall E, Tollefson Travis, Willging Jay Paul, Zdanski Carlton J. Multicenter interrater and intrarater reliability in the endoscopic evaluation of velopharyngeal insufficiency.. Archives of otolaryngology--head & neck surgery. 2008. DOI: 10.1001/archotol.134.7.757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.