Comparing the benefit of ASPECTS on maximum intensity projection images of computed tomography angiography to source images and noncontract computed tomography in predicting infarct volume and collaterals extent.

Ebrahimzadeh Seyed Amir, Du Elizabeth, Ivanovic Vladimir, Bhadelia Rafeeque A, Hacein-Bey Lotfi, Selim Magdy, Chang Yu-Ming

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

In acute ischemic strokes (AIS), the Alberta Stroke Program Early Computed Tomography Score (ASPECTS) and CT perfusion (CTP) are commonly used to determine mechanical thrombectomy eligibility. Prior work suggests that CTA source image (CTA-SI) ASPECTS (CTAasp) and a newly described CTA maximum intensity projection (CTA-MIP) ASPECTS (MIPasp) better predict the final infarct core. Our goal was to compare MIPasp to CTAasp and non-contrast CT ASPECTS (NCCTasp) for predicting ischemic core and collaterals established by CTP.

METHODS AND MATERIALS: A single institution, retrospective database for AIS due to internal carotid artery (ICA) or proximal middle cerebral artery (MCA) occlusions between January 2016 and February 2021 was reviewed. We rated ASPECTS on NCCT, CTA-SI, and CTA-MIP at baseline, then used the automated RAPID software to measure CTP ischemic core volume. The accuracy of each ASPECTS in predicting ischemic core volume (ICV) >70 cc and Hypoperfusion intensity ratio (HIR) >0.4 was compared using the receiver operating characteristic (ROC) curve.

RESULTS

122/319 patients fulfilled the inclusion criteria. Area under the curve (AUC) for MIPasp was significantly higher than NCCTasp and CTAasp for predicting ICV >70 cc (0.95 vs. 0.89 and 0.95 vs. 0.92, P =0.03 and P = 0.04). For predicting HIR >0.4, AUC for MIPasp was significantly higher than NCCTasp and CTAasp (0.85 vs. 0.72 and 0.85 vs. 0.81, P < 0.001 and P < 0.01).

CONCLUSION

The predictive accuracy of detecting ischemic stroke with ICV >70cc and HIR >0.4 can be significantly improved using the MIPasp instead of CTAasp or NCCTasp.

Для цитирования: Ebrahimzadeh Seyed Amir, Du Elizabeth, Ivanovic Vladimir, Bhadelia Rafeeque A, Hacein-Bey Lotfi, Selim Magdy, Chang Yu-Ming. Comparing the benefit of ASPECTS on maximum intensity projection images of computed tomography angiography to source images and noncontract computed tomography in predicting infarct volume and collaterals extent.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2023. DOI: 10.1016/j.jstrokecerebrovasdis.2023.107091.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.