MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology · 2015

[Evidence of waveform information in arterial blood gas by beat-by-beat sampling method in patients with heart failure].

Yao You-xiu, Sun Xing-guo, Li Jun, Tan Xiao-yue, Zhang Hong-liang, Wang Gu-yan, Ge Wan-gang, Liu Fang, Li Hao, Ci Zheng, Hu Sheng-shou

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We investigate the magnitudes of waveform changes of arterial blood gas (ABG) in patients with heart failure.

METHODS

Five patients with heart failure were selected, continuous collecting radial artery blood and measured PaO2, PaCO2, pHa and Sao2. We selected two typical breaths cycles of waveform changes of ABG from each patient for data analysis. Comparison of the adjacent highest and lowest values to verify the presence of a periodic waveform changes of ABG, and in addition, we used t test to analysis the range of waveform changes of ABG in patients with heart failure and patients with normal cardiac function and compared whether the difference between them.

RESULTS

The 5 patients (2 surgical and 3 ICU) with heart failure, were 4 male and 1 female, (69 ± 7)year, (169 ± 10) cm, (75 ± 19)kg, LVEF = (38 ± 3)%. The heart beat numbers for full blood into the blood sampling pipe were 17 ± 2, and all covered more than 2 breath cycles. There were significant changes of PaO2, PaCO2, [H+]a and SaO2 (P < 0.05). The magnitudes of changing PaO2, PaCO2, [H+]a and Sao2 were (7.94 ± 2.02)mmHg, (1.18 ± 0.56)mmHg, (0.54 ± 0.17)nmol/L and (0.21 ± 0.07)%, and they were (6.1 ± 1.5)%, (3.2 ± 1.5)%, (1.5 ± 0.5)% and (0.2 ± 0.1)% from their mean respectively. Even these magnitudes fo all ABG parameters were trendily lower than those of patients with normal cardiac function, but only PaO2 and [H+]a were significant (P < 0.05).

CONCLUSION

Using this simple continuous beat-by-beat arterial blood sampling method, we obtained a clear evidence of periodic waveform of ABG parameters following by breath cycle in patients with heart failure, but the magnitude trendily be decreased.

Для цитирования: Yao You-xiu, Sun Xing-guo, Li Jun, Tan Xiao-yue, Zhang Hong-liang, Wang Gu-yan, Ge Wan-gang, Liu Fang, Li Hao, Ci Zheng, Hu Sheng-shou. [Evidence of waveform information in arterial blood gas by beat-by-beat sampling method in patients with heart failure].. Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.