Медицинская библиотека · Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2017

Automated IMRT planning in Pinnacle : A study in head-and-neck cancer.

Kusters J M A M, Bzdusek K, Kumar P, van Kollenburg P G M, Kunze-Busch M C, Wendling M, Dijkema T, Kaanders J H A M

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA).

METHODS AND MATERIALS: Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer.

RESULTS

Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h.

CONCLUSIONS

The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality.

Для цитирования: Kusters J M A M, Bzdusek K, Kumar P, van Kollenburg P G M, Kunze-Busch M C, Wendling M, Dijkema T, Kaanders J H A M. Automated IMRT planning in Pinnacle : A study in head-and-neck cancer.. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. 2017. DOI: 10.1007/s00066-017-1187-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.