MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5535/arm.2017.41.1.51

Медицинская библиотека · Annals of rehabilitation medicine · 2017

Accuracy of Ultrasound-Guided and Non-ultrasound-Guided Botulinum Toxin Injection Into Cadaver Salivary Glands.

So Jae In, Song Dae Heon, Park Joo Hyun, Choi Eunseok, Yoon Jung Yoon, Yoo Yeonji, Chung Myung Eun

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the accuracy of ultrasound (US)-guided and non-US-guided botulinum toxin (BTX) injection into the salivary glands (parotid and submandibular glands) of cadavers.

METHODS

Two rehabilitation physician injected dye into three sites in the salivary glands (two sites in the parotid gland and one site in the submandibular gland) on one side of each cadaver (one was injected on the right side, while the other was injected on the left side), using either a non-US-guided injection procedure based on superficial landmarks or a US-guided procedure. Orange dye was used for the US-guided procedure, and green dye was used for the blind procedure. Two physicians uninvolved with the injection procedures and who were blinded to the method of injection dissected the cadavers to identify whether the dye was accurately injected into each target site.

RESULTS

The accuracies of the blind and US-guided injections into the parotid gland were 79.17% and 95.83%, respectively. In the submandibular gland, the accuracies of the blind and US-guided injections were 50.00% and 91.67%, respectively. The difference in accuracy between the two procedures was statistically significant only in the submandibular gland (p=0.025). There were no significant differences in the accuracy of US-guided and non-US-guided injections between the two physicians for the two sites in the parotid gland (p=0.278 and p=0.146, respectively).

CONCLUSION

US-guided BTX injection into the submandibular gland offers significantly greater accuracy over blind injection. For the treatment of drooling by injecting BTX into the submandibular gland, clinicians should consider using US guidance for improved accuracy.

Для цитирования: So Jae In, Song Dae Heon, Park Joo Hyun, Choi Eunseok, Yoon Jung Yoon, Yoo Yeonji, Chung Myung Eun. Accuracy of Ultrasound-Guided and Non-ultrasound-Guided Botulinum Toxin Injection Into Cadaver Salivary Glands.. Annals of rehabilitation medicine. 2017. DOI: 10.5535/arm.2017.41.1.51.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.