Tongue Surface Electromyography Detects Reduced Motor Unit Recruitment in Oropharyngeal Cancer Survivors With Hypoglossal Neuropathy.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hansen Nathan J, Hutcheson Katherine A, McMillan Holly, Mao Shitong, Vidad Katelyn, Barbon Carly E, Woodman Karin, Anderson Nicolaas C, Sanchez Benjamin, OPC‐SURVIVOR Program Working Group
Аннотация
BACKGROUND: This proof-of-concept case-control study examined the feasibility of tongue high-density surface electromyography (HDS-EMG) to detect hypoglossal neuropathy.
METHODS: We analyzed tongue HDS-EMG for N = 2 participants. Subjects were graded through clinical tongue functional measures and gold-standard needle EMG. We collected HDS-EMG in three tongue tasks: relaxation, protrusion, and isometric maximum effort. The HDS-EMG was decomposed into motor unit spike train estimates.
RESULTS: Muscle relaxation HDS-EMG contained spikes consistent with fasciculation potential morphology. During tongue protrusion, a case of confirmed CN XII neuropathy exhibited an elevated motor unit (MU) discharge rate and fewer MUs (45.71 peaks/s, 3 estimated MUs) compared to the control (11.63 peaks/s, 11 estimated MUs). During isometric contraction, the case exhibited an average discharge rate of 3.96 peaks/s on 3 MU estimates, whereas the control had a discharge rate of 2.58 peaks/s on 5 MU estimates.
CONCLUSIONS: Non-invasive tongue HDS-EMG appears to show potential sensitivity for detecting reduced MU recruitment in hypoglossal neuropathy.
METHODS: We analyzed tongue HDS-EMG for N = 2 participants. Subjects were graded through clinical tongue functional measures and gold-standard needle EMG. We collected HDS-EMG in three tongue tasks: relaxation, protrusion, and isometric maximum effort. The HDS-EMG was decomposed into motor unit spike train estimates.
RESULTS: Muscle relaxation HDS-EMG contained spikes consistent with fasciculation potential morphology. During tongue protrusion, a case of confirmed CN XII neuropathy exhibited an elevated motor unit (MU) discharge rate and fewer MUs (45.71 peaks/s, 3 estimated MUs) compared to the control (11.63 peaks/s, 11 estimated MUs). During isometric contraction, the case exhibited an average discharge rate of 3.96 peaks/s on 3 MU estimates, whereas the control had a discharge rate of 2.58 peaks/s on 5 MU estimates.
CONCLUSIONS: Non-invasive tongue HDS-EMG appears to show potential sensitivity for detecting reduced MU recruitment in hypoglossal neuropathy.