MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13550-014-0052-4

Медицинская библиотека · EJNMMI research · 2014

Quantification of [(11)C]-meta-hydroxyephedrine uptake in human myocardium.

Harms Hendrik J, de Haan Stefan, Knaapen Paul, Allaart Cornelis P, Rijnierse Mischa T, Schuit Robert C, Windhorst Albert D, Lammertsma Adriaan A, Huisman Marc C, Lubberink Mark

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods.

METHODS

Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (V T) data.

RESULTS

The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, V T derived using the single-tissue model correlated highly with that of the two-tissue model (r (2) = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for single- and two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in V T. RI and SUV can provide misleading results because of non-linear relationships with V T.

CONCLUSIONS

Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with V T, and therefore, care has to be taken when using RI as a quantitative measure.

Для цитирования: Harms Hendrik J, de Haan Stefan, Knaapen Paul, Allaart Cornelis P, Rijnierse Mischa T, Schuit Robert C, Windhorst Albert D, Lammertsma Adriaan A, Huisman Marc C, Lubberink Mark. Quantification of [(11)C]-meta-hydroxyephedrine uptake in human myocardium.. EJNMMI research. 2014. DOI: 10.1186/s13550-014-0052-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.