MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s004249900154

Медицинская библиотека · Pflugers Archiv : European journal of physiology · 2000

Are there systemic changes in the arterial biomechanics of intracranial aneurysm patients?

Tóth M, Nádasy G L, Nyár I, Kerényi T, Monos E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Current theories on the development of intracranial aneurysm suggest that there is a general weakness of vascular connective tissue. Potential systemic alterations in arterial wall biomechanics were tested in the present study. A three-dimensional in vitro stress-strain analysis was made in the 0-200-0 mmHg pressure range on cylindrical segments excised from the anterior cerebral artery, the radial artery and from the arteria dorsalis pedis of aneurysm patients and of control cadavers. In the anterior cerebral artery from aneurysm patients (intracranial artery segments directly not affected by the aneurysm or by the subarachnoid bleeding), we found the wall thickness to be larger (0.1480+/-.019 versus 0.091+/-0.004 mm), the radius/wall thickness ratio smaller (9.7+/-1.4 versus 14.1+/-1.2), and the tangential wall stress lower [(0.122+/-0.019)x10(6) versus (0.181+/-0.016)x10(6) N/m2 at 100 mmHg] than in control subjects. Reduced radius was found in the extremity arteries studied. Elastic parameters, as incremental distensibility and elastic modulus, were remarkable similar. Our study demonstrates changes in the geometry of walls of arteries not directly affected by aneurysm formation, and it thus confirms systemic vascular pathology in this disease. At the same time, these data show that the molecular and morphological defects of arterial connective tissue formation generally thought to induce intracranial aneurysms will probably not affect the components responsible for the passive elastic properties of the vascular wall.

Для цитирования: Tóth M, Nádasy G L, Nyár I, Kerényi T, Monos E. Are there systemic changes in the arterial biomechanics of intracranial aneurysm patients?. Pflugers Archiv : European journal of physiology. 2000. DOI: 10.1007/s004249900154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.