MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-5223(98)70359-9

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 1998

Further evidence of gaseous embolic material in patients with artificial heart valves.

Georgiadis D, Baumgartner R W, Karatschai R, Lindner A, Zerkowski H R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

We undertook this study to evaluate the hypothesis that most microemboli signals in patients with artificial heart valves are gaseous, assuming that microemboli counts in cerebral arteries would progressively decline with increasing distance from the generating heart valve.

METHODS

A total of 10 outpatients with CarboMedics (Sulzer Carbomedics Inc., n = 5) and ATS prosthetic heart valves (n = 5) in the aortic (n = 8), mitral (n = 1), or both aortic and mitral positions (n = 1) were recruited. Monitoring was performed simultaneously over the middle and anterior cerebral arteries and the common carotid artery for 30 minutes with the 2 MHZ transducers of a color duplex scanner (common carotid artery) and pulsed-wave Doppler ultrasonography (intracranial arteries). All data were harvested in an eight-channel digital audio tape recorder, and microembolic signal counts were evaluated online by two separate observers.

RESULTS

Significantly higher microembolic signal counts were recorded in the common carotid artery (112 [75 to 175]) compared with the middle and anterior cerebral arteries (30 [18 to 36], p < 0.0001). Interobserver variability was satisfactory (k = 0.81).

CONCLUSIONS

Our results strongly argue for gaseous underlying embolic material in patients with artificial heart valves because bubbles are bound to implode with time.

Для цитирования: Georgiadis D, Baumgartner R W, Karatschai R, Lindner A, Zerkowski H R. Further evidence of gaseous embolic material in patients with artificial heart valves.. The Journal of thoracic and cardiovascular surgery. 1998. DOI: 10.1016/s0022-5223(98)70359-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.