MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2017.10.007

Медицинская библиотека · The American journal of cardiology · 2017

Outcome of Patients With In-Hospital Ventricular Tachycardia and Ventricular Fibrillation Arrest While Using a Wearable Cardioverter Defibrillator.

Ellenbogen Kenneth A, Wan Chingping, Shavelle David M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In-hospital sudden cardiac arrests occurring during nighttime and weekend hours or within unmonitored hospital areas have been reported to have a poorer outcomes than monitored cardiac arrest. This study sought to assess the outcome of in-hospital ventricular tachycardia (VT) and ventricular fibrillation (VF) arrest by time of day, day of week, and within-hospital location when using a wearable cardioverter defibrillator (WCD). We retrospectively identified and reviewed consecutive in-hospital VT/VF arrests from January 2011 to May 2015 experienced by patients wearing a WCD using the manufacturer's postmarket registry. An index shockable sudden cardiac arrest event was defined as the first arrest caused by VT/VF. Event location and clinical outcome were extracted from patient call logs. Survival analysis was performed using the Kaplan-Meier method. A total of 234 in-hospital VT/VF arrests were included (mean age = 65 ± 12 years, male = 74%); 50% had a history of congestive heart failure. The median follow-up time was 6 days (interquartile range 1-4). In the 128 (55%) daytime events (7:00 a.m. to 7:00 p.m.), 24-hour survival was 91%. The 106 (45%) nighttime events (7:01 p.m. to 6:59 a.m.) had 89% 24-hour survival (p = 0.54). Survival outcome by monitored or unmonitored hospital locations were similar. Kaplan-Meir analyses showed no difference in 30-day survival either between weekend and weekday events (72% vs 65%, p = 0.79), or between daytime and nighttime events (64% vs 69%, p = 0.37). In conclusion, WCD use during in-hospital VT/VF arrest correlated with high survival rates regardless of event time or location inside a hospital. Use of a WCD appears to mitigate some of the risks associated with in-hospital VT/VF arrest.

Для цитирования: Ellenbogen Kenneth A, Wan Chingping, Shavelle David M. Outcome of Patients With In-Hospital Ventricular Tachycardia and Ventricular Fibrillation Arrest While Using a Wearable Cardioverter Defibrillator.. The American journal of cardiology. 2017. DOI: 10.1016/j.amjcard.2017.10.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.