MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-017-1159-1

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2017

Usefulness of the WCD in patients with suspected tachymyopathy.

Erath Julia W, Vamos Mate, Benz Alexander P, Hohnloser Stefan H

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: The wearable cardioverter defibrillator (WCD) is used for temporary protection of patients deemed to be at high risk for sudden death. There is limited experience regarding the clinical development of patients with tachymyopathy. We aimed to evaluate the clinical development of tachymyopathy patients protected with a WCD in a single-center non-randomized patient cohort.

METHODS AND

RESULTS

We fitted 130 consecutive patients deemed to be at high risk for ventricular tachyarrhythmias with the WCD. Of these, 20 patients (15%) presenting with newly diagnosed heart failure in the setting of rapidly conducted atrial fibrillation/flutter were suspected to suffer from tachymyopathy. The control group consisted of the remaining 110 patients with other indications for WCD therapy. LVEF increased by more than 10% in 13/20 (65%) tachymyopathy patients compared to 40/110 (36%) patients in the control population (p = 0.01). Similarly, BNP levels decreased in 15/20 (75%) tachymyopathy patients compared to 41/110 (37%) in the control group (p = 0.05). ICD implantation rates were lower in the tachymyopathy group (3/20) compared to the control population (40/110; p = 0.04). On further follow-up (mean 12 ± 8 months), patients with suspected tachymyopathy had no sustained ventricular arrhythmias. Compared to 5/110 patients in the control group, no tachymyopathy patient died.

CONCLUSION

Most of the patients with suspected tachymyopathy have a favorable clinical outcome. The WCD is useful for temporary protection while LV function recovers.

Для цитирования: Erath Julia W, Vamos Mate, Benz Alexander P, Hohnloser Stefan H. Usefulness of the WCD in patients with suspected tachymyopathy.. Clinical research in cardiology : official journal of the German Cardiac Society. 2017. DOI: 10.1007/s00392-017-1159-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.