Area asymmetry of heart rate variability signal.

Yan Chang, Li Peng, Ji Lizhen, Yao Lianke, Karmakar Chandan, Liu Changchun

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Heart rate fluctuates beat-by-beat asymmetrically which is known as heart rate asymmetry (HRA). It is challenging to assess HRA robustly based on short-term heartbeat interval series.

METHOD: An area index (AI) was developed that combines the distance and phase angle information of points in the Poincaré plot. To test its performance, the AI was used to classify subjects with: (i) arrhythmia, and (ii) congestive heart failure, from the corresponding healthy controls. For comparison, the existing Porta's index (PI), Guzik's index (GI), and slope index (SI) were calculated. To test the effect of data length, we performed the analyses separately using long-term heartbeat interval series (derived from >3.6-h ECG) and short-term segments (with length of 500 intervals). A second short-term analysis was further carried out on series extracted from 5-min ECG.

RESULTS

For long-term data, SI showed acceptable performance for both tasks, i.e., for task i p < 0.001, Cohen's d = 0.93, AUC (area under the receiver-operating characteristic curve) = 0.86; for task ii p < 0.001, d = 0.88, AUC = 0.75. AI performed well for task ii (p < 0.001, d = 1.0, AUC = 0.78); for task i, though the difference was statistically significant (p < 0.001, AUC = 0.76), the effect size was small (d = 0.11). PI and GI failed in both tasks (p > 0.05, d < 0.4, AUC < 0.7 for all). However, for short-term segments, AI indicated better distinguishability for both tasks, i.e., for task i, p < 0.001, d = 0.71, AUC = 0.71; for task ii, p < 0.001, d = 0.93, AUC = 0.74. The rest three measures all failed with small effect sizes and AUC values (d < 0.5, AUC < 0.7 for all) although the difference in SI for task i was statistically significant (p < 0.001). Besides, AI displayed smaller variations across different short-term segments, indicating more robust performance. Results from the second short-term analysis were in keeping with those findings.

CONCLUSION

The proposed AI indicated better performance especially for short-term heartbeat interval data, suggesting potential in the ambulatory application of cardiovascular monitoring.

Для цитирования: Yan Chang, Li Peng, Ji Lizhen, Yao Lianke, Karmakar Chandan, Liu Changchun. Area asymmetry of heart rate variability signal.. Biomedical engineering online. 2017. DOI: 10.1186/s12938-017-0402-3.