MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-11-0733

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2011

Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve.

Okamura Homare, Yamaguchi Atsushi, Nagano Hiroshi, Itoh Satoshi, Morita Hideki, Naito Kazuhiro, Yuri Koichi, Adachi Hideo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

When aortic valve replacement (AVR) is performed in patients with a small aortic annulus, prosthesis-patient mismatch (PPM) is of concern. We investigated the mid-term outcomes of AVR with a 17-mm mechanical prosthesis.

METHODS AND

RESULTS

Seventy-eight patients with aortic stenosis underwent AVR with a 17-mm St. Jude Medical Regent prosthesis. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean follow-up, 33 months). Patients were divided into 2 groups: with and without PPM at discharge. Between-group differences in postoperative variables, particularly survival, were analyzed. Overall hospital mortality was 2.6%. Actuarial 1- and 5-year survival rates were 95% and 79%, respectively. Diabetes and renal insufficiency were associated with long-term mortality. Freedom from major adverse valve-related cardiac events at 1 year and 5 years was 97.3% and 93.9%, respectively. Diabetes was shown to be an independent risk factor for major adverse valve-related cardiac events. Echocardiography 13 months after AVR showed a significant increase in mean effective orifice area index, decrease in mean left ventricular-aortic pressure gradient, and decrease in mean left ventricular mass index. PPM at discharge did not influence long-term survival or left ventricular mass regression.

CONCLUSIONS

The 17-mm Regent prosthesis provided satisfactory clinical and hemodynamic results. It is a reliable choice for patients with a small aortic annulus.

Для цитирования: Okamura Homare, Yamaguchi Atsushi, Nagano Hiroshi, Itoh Satoshi, Morita Hideki, Naito Kazuhiro, Yuri Koichi, Adachi Hideo. Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve.. Circulation journal : official journal of the Japanese Circulation Society. 2011. DOI: 10.1253/circj.cj-11-0733.