MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.23240

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2011

Clinical outcome of transcatheter aortic valve implantation in patients with low-flow, low gradient aortic stenosis.

Gotzmann Michael, Lindstaedt Michael, Bojara Waldemar, Ewers Aydan, Mügge Andreas

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Low-flow, low-gradient aortic stenosis is associated with relevant postoperative mortality whereas conservative management results in dismal prognosis. We present the initial experience of low-flow, low-gradient aortic stenosis treated with transcatheter aortic valve implantation (TAVI).

METHODS

From June 2008 to December 2010 167 consecutive patients with native severe aortic stenosis and an excessive operative risk underwent TAVI. Of these, 15 patients presented with low-flow, low-gradient aortic stenosis (aortic valve area < 1 cm(2) , left ventricular (LV) ejection fraction < 40%, aortic mean gradient < 40 mm Hg). The CoreValve prosthesis 18-F-generation (Medtronic, Minneapolis, Minnesota) was inserted retrograde. Clinical follow-up and echocardiography were performed 6 months after procedure.

RESULTS

Patients with low-flow, low-gradient aortic stenosis (mean LV ejection fraction 32 ± 6%, mean aortic gradient 27 ± 7 mm Hg) had higher all-cause mortality 6 months after TAVI compared to patients without low-flow, low-gradient aortic stenosis (33% vs. 13%, P = 0.037). In the surviving 10 patients with low-flow, low-gradient aortic stenosis, LV ejection fraction increased (34 ± 6% before vs. 46 ± 11% 6 months after TAVI, p = 0.005) and more distance covered in the 6-minute walk test (218 ± 102 meters before vs. 288 ± 129 meters 6 months after TAVI, p = 0.038).

CONCLUSION

Our study suggests that TAVI is feasible in patients with severe co-morbidities and low-flow, low-gradient aortic stenosis. Within the first 6 months after treatment all-cause mortality was considerable high, but the surviving patients showed symptomatic benefit and significant improvement of myocardial function and exercise capacity.

Для цитирования: Gotzmann Michael, Lindstaedt Michael, Bojara Waldemar, Ewers Aydan, Mügge Andreas. Clinical outcome of transcatheter aortic valve implantation in patients with low-flow, low gradient aortic stenosis.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2011. DOI: 10.1002/ccd.23240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.