MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2011.05.015

Медицинская библиотека · Heart rhythm · 2011

Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections.

Le Katherine Y, Sohail Muhammad R, Friedman Paul A, Uslan Daniel Z, Cha Stephen S, Hayes David L, Wilson Walter R, Steckelberg James M, Baddour Larry M, Mayo Cardiovascular Infections Study Group

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiovascular implantable electronic device (CIED) infections are associated with increased mortality. However, detailed analyses of the impact of device removal on mortality have been limited.

OBJECTIVE

This study sought to evaluate the impact of timing device removal on mortality in patients with CIED infections.

METHODS

We retrospectively reviewed all cases of CIED infections seen at Mayo Clinic Rochester between 1991 and 2008. The impact of device removal on 30-day and 1-year mortality was evaluated using Cox proportional hazards models.

RESULTS

Of 416 patients with CIED infection, 23 (5.5%) died by 30 days and 61 (14.6%) died by 1 year. Forty-four (12.0%) developed complications related to device removal, and 3 (0.8%) died. Complete procedural success was achieved in 341 (81.9%) and clinical success in 391 (93.9%) cases. In multivariate analysis, antimicrobial therapy without device removal was associated with a 7-fold increase in 30-day mortality (hazard ratio [HR] 6.97, 95% confidence interval [CI] 1.36 to 35.60). Although device removal complications were associated with increased mortality at 30 days (HR 4.33, 95% CI 1.47 to 12.70) and at 1 year (HR 3.77, 95% CI 1.88 to 7.55), immediate device removal, when compared to delay in device removal in favor of initial conservative therapy with antimicrobials alone, and no device removal, was associated with a 3-fold decrease in 1-year mortality (HR 0.35, 95% CI 0.16 to 0.75).

CONCLUSION

Although device removal resulted in fatal complications in a few patients, the mortality associated with a delay in device removal was significantly higher. Therefore, early and complete device removal was associated with improved outcomes.

Для цитирования: Le Katherine Y, Sohail Muhammad R, Friedman Paul A, Uslan Daniel Z, Cha Stephen S, Hayes David L, Wilson Walter R, Steckelberg James M, Baddour Larry M, Mayo Cardiovascular Infections Study Group. Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections.. Heart rhythm. 2011. DOI: 10.1016/j.hrthm.2011.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.