MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.13637

Медицинская библиотека · Contact dermatitis · 2020

Clinical factors before or after device implantation in predicting metal hypersensitivity reactions: A retrospective study.

Tam Idy, Yu JiaDe, Ko Lauren N, Schalock Peter C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Metal hypersensitivity reactions (MHR) as a cause of implant-related complications are highly debated and recommendations regarding pre-procedural allergy evaluation vary dramatically.

OBJECTIVE

To examine patients referred before or after device implantation and identify factors that could be useful to guide the value of patch testing.

METHODS

Patients who underwent patch testing pre- or post-device implantation between July 2006 and September 2016 were analyzed retrospectively.

RESULTS

A series of 127 patients underwent patch testing: pre-implantation (n = 40) and post-implantation (n = 87). In the pre-implant group, a history of metal allergy demonstrated high sensitivity (0.94; 95% CI: 0.83-1.00) and negative likelihood ratio (0.17; 95% CI:0.02-1.29) for diagnosing MHR. No predictive value could be ascribed to any of the clinical symptoms (eg dermatitis, pain, swelling, implant failure, and/or other symptoms) for patients referred following orthopaedic and dental post device implantation. Eight patients in the orthopaedic group and six patients in dental group with relevant patch test reactions underwent implant revisions, and seven and five patients improved, respectively.

CONCLUSIONS

Pre-implant patch testing for selected individuals with a history of metal allergy can help guide implant choice. Post-implant patch testing may be helpful in some patients if other causes have been excluded, as patients with confirmed MHR benefited from revisions.

Для цитирования: Tam Idy, Yu JiaDe, Ko Lauren N, Schalock Peter C. Clinical factors before or after device implantation in predicting metal hypersensitivity reactions: A retrospective study.. Contact dermatitis. 2020. DOI: 10.1111/cod.13637.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.