MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00432-003-0528-5

Медицинская библиотека · Journal of cancer research and clinical oncology · 2004

Prophylaxis of port system-associated thromboses in advanced oncology patients using heparin flushing.

Lersch C, Kotowa W, Fung S, Janssen D

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Thromboses occur in connection with the use of venous port systems. Valid data on the instillation of heparin-based solutions in the lumen of the port system are lacking.

METHODS

One hundred and seventy-three patients with malignancy from 19 centres who had participated in an observation study of subcutaneous thromboprophylaxis with dalteparin-Na (Fragmin P/-Forte) were analysed with a view to flushing the port systems and investigating any related influence on the occurrence of catheter-associated thromboses.

RESULTS

All catheter-associated thromboses were seen in centres which used either no UFH, or UFH concentrations of up to 250 IU/ml (8/108; 7.4%). The rate of thrombosis rose to 10% (6/60) if no high-risk dose of dalteparin was applied subcutaneously. On the other hand, the rate of catheter-associated thromboses under the high-risk dose of dalteparin and/or a more highly concentrated instillation fluid, at 0.9% (1/113), was much lower. One haemorrhage from gastric ulcer occurred under the highest UFH concentration in the instillation fluid (2,500 IU UFH/ml).

CONCLUSION

The results indicate that a concentration between 500 IU UFH/ml and 1,000 IU UFH/ml in the instillation solution, at the same time as high-risk prophylaxis with subcutaneous dalteparin for prevention of catheter-associated thromboses, is effective in patients with manifest tumour disease. The instillation of LMWH-based solutions at a concentration of approx 500 anti-Xa units/ml should be discussed as a pending issue.

Для цитирования: Lersch C, Kotowa W, Fung S, Janssen D. Prophylaxis of port system-associated thromboses in advanced oncology patients using heparin flushing.. Journal of cancer research and clinical oncology. 2004. DOI: 10.1007/s00432-003-0528-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.