On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity.

Thielens Arno, Agneessens Sam, De Clercq Hans, Lecoutere Jeroen, Verloock Leen, Tanghe Emmeric, Aerts Sam, Puers Robert, Rogier Hendrik, Martens Luc, Joseph Wout

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This paper describes the design, calibration, and measurements with a personal, distributed exposimeter (PDE) for the on-body detection of radio frequency (RF) electromagnetic fields due to Wireless Fidelity (WiFi) networks. Numerical simulations show that using a combination of two RF nodes placed on the front and back of the body reduces the 50% prediction interval (PI50) on the incident free-space electric-field strength (Equation is included in full-text article.). Median reductions of 10 dB and 9.1 dB are obtained compared to the PI50 of a single antenna placed on the body using a weighted arithmetic and geometric average, respectively. Therefore, a simple PDE topology based on two nodes, which are deployed on opposite sides of the human torso, is applied for calibration and measurements. The PDE is constructed using flexible, dual-polarized textile antennas and wearable electronics, which communicate wirelessly with a Universal Serial Bus (USB) connected receiver and can be unobtrusively integrated into a garment. The calibration of the PDE in an anechoic chamber proves that the PI50 of the measured (Equation is included in full-text article.)is reduced to 3.2 dB. To demonstrate the real-life usability of the wireless device, a subject was equipped with the PDE during a walk in the city of Ghent, Belgium. Using a sample frequency of 2 Hz, an average incident power density of 59 nW m was registered in the WiFi frequency band during this walk.

Для цитирования: Thielens Arno, Agneessens Sam, De Clercq Hans, Lecoutere Jeroen, Verloock Leen, Tanghe Emmeric, Aerts Sam, Puers Robert, Rogier Hendrik, Martens Luc, Joseph Wout. On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity.. Health physics. 2015. DOI: 10.1097/hp.0000000000000238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.