MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/japplphysiol.01189.2013

Медицинская библиотека · Journal of applied physiology (Bethesda, Md. : 1985) · 2015

Automatic identification of physical activity types and sedentary behaviors from triaxial accelerometer: laboratory-based calibrations are not enough.

Bastian Thomas, Maire Aurélia, Dugas Julien, Ataya Abbas, Villars Clément, Gris Florence, Perrin Emilie, Caritu Yanis, Doron Maeva, Blanc Stéphane, Jallon Pierre, Simon Chantal

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

"Objective" methods to monitor physical activity and sedentary patterns in free-living conditions are necessary to further our understanding of their impacts on health. In recent years, many software solutions capable of automatically identifying activity types from portable accelerometry data have been developed, with promising results in controlled conditions, but virtually no reports on field tests. An automatic classification algorithm initially developed using laboratory-acquired data (59 subjects engaging in a set of 24 standardized activities) to discriminate between 8 activity classes (lying, slouching, sitting, standing, walking, running, and cycling) was applied to data collected in the field. Twenty volunteers equipped with a hip-worn triaxial accelerometer performed at their own pace an activity set that included, among others, activities such as walking the streets, running, cycling, and taking the bus. Performances of the laboratory-calibrated classification algorithm were compared with those of an alternative version of the same model including field-collected data in the learning set. Despite good results in laboratory conditions, the performances of the laboratory-calibrated algorithm (assessed by confusion matrices) decreased for several activities when applied to free-living data. Recalibrating the algorithm with data closer to real-life conditions and from an independent group of subjects proved useful, especially for the detection of sedentary behaviors while in transports, thereby improving the detection of overall sitting (sensitivity: laboratory model = 24.9%; recalibrated model = 95.7%). Automatic identification methods should be developed using data acquired in free-living conditions rather than data from standardized laboratory activity sets only, and their limits carefully tested before they are used in field studies.

Для цитирования: Bastian Thomas, Maire Aurélia, Dugas Julien, Ataya Abbas, Villars Clément, Gris Florence, Perrin Emilie, Caritu Yanis, Doron Maeva, Blanc Stéphane, Jallon Pierre, Simon Chantal. Automatic identification of physical activity types and sedentary behaviors from triaxial accelerometer: laboratory-based calibrations are not enough.. Journal of applied physiology (Bethesda, Md. : 1985). 2015. DOI: 10.1152/japplphysiol.01189.2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.