Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2* determination.

Triadyaksa Pandji, Prakken Niek H J, Overbosch Jelle, Peters Robin B, van Swieten J Martijn, Oudkerk Matthijs, Sijens Paul E

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Early detection of iron loading is affected by the reproducibility of myocardial contour assessment. A novel semi-automatic myocardial segmentation method is presented on contrast-optimized composite images and compared to the results of manual drawing.

MATERIALS AND

METHODS

Fifty-one short-axis slices at basal, mid-ventricular and apical locations from 17 patients were acquired by bright blood multi-gradient echo MRI. Four observers produced semi-automatic and manual myocardial contours on contrast-optimized composite images. The semi-automatic segmentation method relies on vector field convolution active contours to generate the endocardial contour. After creating radial pixel clusters on the myocardial wall, a combination of pixel-wise coefficient of variance (CoV) assessment and k-means clustering establishes the epicardial contour for each segment.

RESULTS

Compared to manual drawing, semi-automatic myocardial segmentation lowers the variability of T2* quantification within and between observers (CoV of 12.05 vs. 13.86% and 14.43 vs. 16.01%) by improving contour reproducibility (P < 0.001). In the presence of iron loading, semi-automatic segmentation also lowers the T2* variability within and between observers (CoV of 13.14 vs. 15.19% and 15.91 vs. 17.28%).

CONCLUSION

Application of semi-automatic myocardial segmentation on contrast-optimized composite images improves the reproducibility of T2* quantification.

Для цитирования: Triadyaksa Pandji, Prakken Niek H J, Overbosch Jelle, Peters Robin B, van Swieten J Martijn, Oudkerk Matthijs, Sijens Paul E. Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2* determination.. Magma (New York, N.Y.). 2016. DOI: 10.1007/s10334-016-0601-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.