MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2020.04.008

Медицинская библиотека · Brachytherapy · 2020

A knowledge-based organ dose prediction tool for brachytherapy treatment planning of patients with cervical cancer.

Yusufaly Tahir I, Kallis Karoline, Simon Aaron, Mayadev Jyoti, Yashar Catheryn M, Einck John P, Mell Loren K, Brown Derek, Scanderbeg Daniel, Hild Sebastian J, Covele Brent, Moore Kevin L, Meyers Sandra M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study is to explore knowledge-based organ-at-risk dose estimation for intracavitary brachytherapy planning for cervical cancer. Using established external-beam knowledge-based dose-volume histogram (DVH) estimation methods, we sought to predict bladder, rectum, and sigmoid D2cc for tandem and ovoid treatments.

METHODS AND MATERIALS: A total of 136 patients with loco-regionally advanced cervical cancer treated with 456 (356:100 training:validation ratio) CT-based tandem and ovoid brachytherapy fractions were analyzed. Single fraction prescription doses were 5.5-8 Gy with dose criteria for the high-risk clinical target volume, bladder, rectum, and sigmoid. DVH estimations were obtained by subdividing training set organs-at-risk into high-risk clinical target volume boundary distance subvolumes and computing cohort-averaged differential DVHs. Full DVH estimation was then performed on the training and validation sets. Model performance was quantified by ΔD2cc = D2cc(actual)-D2cc(predicted) (mean and standard deviation). ΔD2cc between training and validation sets were compared with a Student's t test (p < 0.01 significant). Categorical variables (physician, fraction-number, total fractions, and case complexity) that might explain model variance were examined using an analysis of variance test (Bonferroni-corrected p < 0.01 threshold).

RESULTS

Training set deviations were bladder ΔD2cc = -0.04 ± 0.61 Gy, rectum ΔD2cc = 0.02 ± 0.57 Gy, and sigmoid ΔD2cc = -0.05 ± 0.52 Gy. Model predictions on validation set did not statistically differ: bladder ΔD2cc = -0.02 ± 0.46 Gy (p = 0.80), rectum ΔD2cc = -0.007 ± 0.47 Gy (p = 0.53), and sigmoid ΔD2cc = -0.07 ± 0.47 Gy (p = 0.70). The only significant categorical variable was the attending physician for bladder and rectum ΔD2cc.

CONCLUSION

A simple boundary distance-driven knowledge-based DVH estimation exhibited promising results in predicting critical brachytherapy dose metrics. Future work will examine the utility of these predictions for quality control and automated brachytherapy planning.

Для цитирования: Yusufaly Tahir I, Kallis Karoline, Simon Aaron, Mayadev Jyoti, Yashar Catheryn M, Einck John P, Mell Loren K, Brown Derek, Scanderbeg Daniel, Hild Sebastian J, Covele Brent, Moore Kevin L, Meyers Sandra M. A knowledge-based organ dose prediction tool for brachytherapy treatment planning of patients with cervical cancer.. Brachytherapy. 2020. DOI: 10.1016/j.brachy.2020.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.