DOI 10.1186/s12876-020-01257-4
Narrow-band imaging and high-definition white-light endoscopy in patients with serrated lesions not fulfilling criteria for serrated polyposis syndrome: a randomized controlled trial with tandem colonoscopy.
Аннотация
BACKGROUND
It is unknown whether narrow-band imaging (NBI) could be more effective than high-definition white-light endoscopy (HD-WLE) in detecting serrated lesions in patients with prior serrated lesions > 5 mm not completely fulfilling serrated polyposis syndrome (SPS) criteria.
METHODS
We conducted a randomized, cross-over trial in consecutive patients with prior detection of at least one serrated polyp ≥10 mm or ≥ 3 serrated polyps larger than 5 mm, both proximal to the sigmoid colon. Five experienced endoscopists performed same-day tandem colonoscopies, with the order being randomized 1:1 to NBI-HD-WLE or HD-WLE-NBI. All tandem colonoscopies were performed by the same endoscopist.
RESULTS
We included 41 patients. Baseline characteristics were similar in the two cohorts: NBI-HD-WLE (n = 21) and HD-WLE-NBI (n = 20). No differences were observed in the serrated lesion detection rate of NBI versus HD-WLE: 47.4% versus 51.9% (OR 0.84, 95% CI: 0.37-1.91) for the first and second withdrawal, respectively. Equally, no differences were found in the polyp miss rate of NBI versus HD-WLE: 21.3% versus 26.1% (OR 0.77, 95% CI: 0.43-1.38). Follow-up colonoscopy in nine patients (22%) allowed them to be reclassified as having SPS.
CONCLUSIONS
In patients with previous serrated lesions, the serrated lesion detection rate was similar with NBI and HD-WLE. A shorter surveillance colonoscopy interval increases the detection of missed serrated polyps and could change the diagnosis of SPS in approximately one in every five patients.
TRIAL REGISTRATION: ClinicalTrials.gov NCT02406547, registered on April 2, 2015.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.