MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2019.06.042

Медицинская библиотека · Gastrointestinal endoscopy · 2019

Impact of a ring-fitted cap on insertion time and adenoma detection: a randomized controlled trial.

Rex Douglas K, Kessler William R, Sagi Sashidhar V, Rogers Nicholas A, Fischer Monika, Bohm Matthew E, Wo John M, Dewitt John M, McHenry Lee, Lahr Rachel E, Searight Meghan P, MacPhail Margaret, Sullivan Andrew W, McWhinney Connor D, Vemulapalli Krishna C

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring-fitted cap (EndoRings; EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy.

METHODS

This was a single-center, randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate, insertion times, withdrawal times, and ease of passage through the sigmoid colon.

RESULTS

EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, P = .025), but there were no statistically significant differences in ADR or sessile serrated polyp detection rate. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with Endo-Rings and contributed substantially to the overall results.

CONCLUSIONS

EndoRings can increase adenoma detection without a significant increase in procedure time, but the effect varies between operators. The use of EndoRings slows colonoscope insertion. (Clinical trial registration number: NCT03418662.).

Для цитирования: Rex Douglas K, Kessler William R, Sagi Sashidhar V, Rogers Nicholas A, Fischer Monika, Bohm Matthew E, Wo John M, Dewitt John M, McHenry Lee, Lahr Rachel E, Searight Meghan P, MacPhail Margaret, Sullivan Andrew W, McWhinney Connor D, Vemulapalli Krishna C. Impact of a ring-fitted cap on insertion time and adenoma detection: a randomized controlled trial.. Gastrointestinal endoscopy. 2019. DOI: 10.1016/j.gie.2019.06.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.