MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2012.01.008

Медицинская библиотека · Academic radiology · 2012

A new formula for rapid assessment of pericardial effusion volume by computed tomography.

Groth Michael, Regier Marc, Muellerleile Kai, Bannas Peter, Adam Gerhard, Henes Frank Oliver

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The aim of this study was to evaluate a new formula for the rapid assessment of pericardial effusion (PE) volume by computed tomography.

MATERIALS AND

METHODS

Twenty computed tomographic scans positive for PE were reviewed by two observers. Diameters of PE were measured at four locations. Additionally, PE volume was assessed by volumetry. The correlation between PE diameters and volume was evaluated, and a linear equation was derived for each diameter location. To test validity and reliability of the measurements, intraclass correlation and Bland-Altman analysis were performed.

RESULTS

Good validity was expressed by strong correlations between diameter measurements at all four locations and PE volume (all R values >0.80 and P values <.0001). Intraclass correlation (all coefficients >0.75) and Bland-Altman analysis revealed good interobserver and intraobserver reliability of diameter measurements. The best values were observed for apical diameter measurements. The following linear equation was derived for apical diameter measurements: PE volume = 296 (mL/cm) × apical diameter (cm) - 32 mL.

CONCLUSIONS

PE volume can rapidly be assessed by apical PE diameter measurement using the simplified formula PE volume = 0.3 (L/cm) × apical diameter (cm).

Для цитирования: Groth Michael, Regier Marc, Muellerleile Kai, Bannas Peter, Adam Gerhard, Henes Frank Oliver. A new formula for rapid assessment of pericardial effusion volume by computed tomography.. Academic radiology. 2012. DOI: 10.1016/j.acra.2012.01.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.