Development of a Two Stage Pipeline for Robust Pulmonary Nodule Detection in Consecutive CT Slices.

Wu Jiancheng, Tian Miao, Zeng Liaoyuan, Xia Yujie, McGrath Sean

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Current pulmonary nodule detection systems often neglect the spatiotemporal continuity inherent in computed tomography (CT) sequences within a single scan. They treat individual slices as independent images and lack mechanisms to recover missed detections. As a result, nodules missed in individual slices cannot be recovered. This study aims to develop a detection-tracking co-design framework that improves both sensitivity and specificity for pulmonary nodule detection.

Methods

We propose a detection-tracking co-design framework. It couples an enhanced YOLOX detector with a Kalman filter-based tracker in Stage I, to associate nodule candidates across consecutive slices and recover missed detections. Stage II employs cross-slice Maximum Intensity Projection and a lightweight ResNet-50 classifier, to reduce false positives through morphological feature discrimination.

Results

Systematic ablation studies on the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset using the criteria of the Lung Nodule Analysis 2016 (LUNA16) dataset demonstrate the complementary contributions of each component. The complete framework achieves a Competition Performance Metric (CPM) score of 0.9344 and exhibits particular strength in medium-to-high sensitivity regions.

Conclusions

The proposed detection-tracking co-design provides an interpretable paradigm that balances high sensitivity and improved specificity, offering a promising solution for computer-aided diagnosis of pulmonary nodules.

Для цитирования: Wu Jiancheng, Tian Miao, Zeng Liaoyuan, Xia Yujie, McGrath Sean. Development of a Two Stage Pipeline for Robust Pulmonary Nodule Detection in Consecutive CT Slices.. Biomedicines. 2026. DOI: 10.3390/biomedicines14091923.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.