MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.nuclcard.2003.11.005

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2004

Compared with 3-dimensional analysis, 2-dimensional gated SPECT analysis overestimates left ventricular ejection fraction in patients with regional dyssynchrony.

Kasai Tokuo, Depuey E Gordon, Shah Arshad Ali

Клиническое исследованиеСравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Left ventricular (LV) ejection fraction (EF) is a powerful prognostic predictor in patients with heart disease. However, LVEF calculated by 2-dimensional (2D) modalities such as echocardiography by use of the "modified" Simpson's rule may be incorrect in patients with regional dyssynchrony, presumably because regions of dyssynchrony are excluded from analysis.

METHODS AND

RESULTS

To elucidate the difference between 2D and 3-dimensional (3D) methods with regard to LVEF calculation in patients with regional dyssynchrony, we compared LVEF derived from 8-frame gated technetium 99m sestamibi stress perfusion tomograms using commercially available 2D single photon emission computed tomography (SPECTEF) software that uses the modified Simpson's rule, 3D QGS, and investigational 3D p-FAST software in 136 left bundle branch block patients. Twenty-four patients had normal wall motion, whereas one hundred twelve showed septal dyssynchrony. Bland-Altman plots demonstrated that compared with QGS and p-FAST, SPECTEF overestimated LVEF in patients with septal dyssynchrony systemically by 8.6% and 11.3%, respectively.

CONCLUSIONS

We conclude that compared with 3D modalities, 2D modalities that use the modified Simpson's rule, such as SPECT EF, overestimate LVEF in patients with dyssynchronous septal wall motion. Therefore 3D modalities are preferred to evaluate patients with regional dyssynchrony.

Для цитирования: Kasai Tokuo, Depuey E Gordon, Shah Arshad Ali. Compared with 3-dimensional analysis, 2-dimensional gated SPECT analysis overestimates left ventricular ejection fraction in patients with regional dyssynchrony.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2004. DOI: 10.1016/j.nuclcard.2003.11.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.