Value of heart rate variability to predict ventricular arrhythmias in recipients of prophylactic defibrillators with idiopathic dilated cardiomyopathy.

Grimm Wolfram, Herzum Ileana, Müller Hans-Helge, Christ Michael

СтатьяПеревод пока не подготовлен

Аннотация

This study investigated the relation between heart rate variability (HRV) measured as standard deviation of normal to normal RR intervals (SDNN) on baseline 24-hour ambulatory electrocardiogram (ECG) and subsequent appropriate implantable cardioverter defibrillator (ICD) interventions in 70 patients with idiopathic dilated cardiomyopathy (IDC) in whom ICDs were implanted prophylactically in the presence of a low left ventricular ejection fraction (LVEF). During 43 +/- 26 months of follow-up, 26 of 70 (37%) study patients with IDC received one or more appropriate ICD interventions for sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) documented by electrograms stored in the ICD. Mean SDNN at ICD implant was 94 +/- 33 ms. No difference was found between patients with (90 +/- 25 ms) versus without (96 +/- 37 ms) appropriate ICD interventions for VT or VF during follow-up. Multivariate Cox regression analysis of baseline clinical characteristics including age, gender, LVEF, NYHA functional class, nonsustained VT on Holter, history of syncope, left bundle branch block, baseline medication and HRV revealed LVEF as the only significant predictor of arrhythmia. These findings do not support the use of HRV measured as SDNN on 24-hour ambulatory ECG to select patients with IDC for prophylactic ICD therapy.

Для цитирования: Grimm Wolfram, Herzum Ileana, Müller Hans-Helge, Christ Michael. Value of heart rate variability to predict ventricular arrhythmias in recipients of prophylactic defibrillators with idiopathic dilated cardiomyopathy.. Pacing and clinical electrophysiology : PACE. 2003. DOI: 10.1046/j.1460-9592.2003.00060.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.