MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-024-06938-w

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2024

Spiral volumetric optoacoustic tomography of reduced oxygen saturation in the spinal cord of M83 mouse model of Parkinson's disease.

Combes Benjamin F, Kalva Sandeep Kumar, Benveniste Pierre-Louis, Tournant Agathe, Law Man Hoi, Newton Joshua, Krüger Maik, Weber Rebecca Z, Dias Inês, Noain Daniela, Dean-Ben Xose Luis, Konietzko Uwe, Baumann Christian R, Gillberg Per-Göran, Hock Christoph, Nitsch Roger M, Cohen-Adad Julien, Razansky Daniel, Ni Ruiqing

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Metabolism and bioenergetics in the central nervous system play important roles in the pathophysiology of Parkinson's disease (PD). Here, we employed a multimodal imaging approach to assess oxygenation changes in the spinal cord of the transgenic M83 murine model of PD overexpressing the mutated A53T alpha-synuclein form in comparison with non-transgenic littermates.

METHODS

In vivo spiral volumetric optoacoustic tomography (SVOT) was performed to assess oxygen saturation (sO2) in the spinal cords of M83 mice and non-transgenic littermates. Ex vivo high-field T1-weighted (T1w) magnetic resonance imaging (MRI) at 9.4T was used to assess volumetric alterations in the spinal cord. 3D SVOT analysis and deep learning-based automatic segmentation of T1w MRI data for the mouse spinal cord were developed for quantification. Immunostaining for phosphorylated alpha-synuclein (pS129 α-syn), as well as vascular organization (CD31 and GLUT1), was performed after MRI scan.

RESULTS

In vivo SVOT imaging revealed a lower sO2SVOT in the spinal cord of M83 mice compared to non-transgenic littermates at sub-100 μm spatial resolution. Ex vivo MRI-assisted by in-house developed deep learning-based automatic segmentation (validated by manual analysis) revealed no volumetric atrophy in the spinal cord of M83 mice compared to non-transgenic littermates at 50 μm spatial resolution. The vascular network was not impaired in the spinal cord of M83 mice in the presence of pS129 α-syn accumulation.

CONCLUSION

We developed tools for deep-learning-based analysis for the segmentation of mouse spinal cord structural MRI data, and volumetric analysis of sO2SVOT data. We demonstrated non-invasive high-resolution imaging of reduced sO2SVOT in the absence of volumetric structural changes in the spinal cord of PD M83 mouse model.

Для цитирования: Combes Benjamin F, Kalva Sandeep Kumar, Benveniste Pierre-Louis, Tournant Agathe, Law Man Hoi, Newton Joshua, Krüger Maik, Weber Rebecca Z, Dias Inês, Noain Daniela, Dean-Ben Xose Luis, Konietzko Uwe, Baumann Christian R, Gillberg Per-Göran, Hock Christoph, Nitsch Roger M, Cohen-Adad Julien, Razansky Daniel, Ni Ruiqing. Spiral volumetric optoacoustic tomography of reduced oxygen saturation in the spinal cord of M83 mouse model of Parkinson's disease.. European journal of nuclear medicine and molecular imaging. 2024. DOI: 10.1007/s00259-024-06938-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.