MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0300-8932(02)76568-8

Медицинская библиотека · Revista espanola de cardiologia · 2002

[Is troponin I useful for predicting in-hospital risk for unstable angina patients in a community hospital? Results of a prospective study].

Bodí Vicente V, Sanchis Juan, Llácer Angel, Graells María L, Llorca Lourdes, Chorro Francisco J, Insa Luis D, Navarro Alejandro, Plancha Eva, Cortés Francisco J, Ponce De León Juan C, Valls Amparo

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVES

Before including troponin I detection in the daily practice of our hospital we performed a prospective study to determine its real usefulness and to establish the best cut-off point.

METHODS

We studied 82 consecutive patients admitted with unstable angina to a community hospital. Troponin I was determined (> 10 h after chest pain). Patients were referred to a tertiary hospital for catheterization/revascularization if clinical events developed.

RESULTS

Twenty-five patients (31%) suffered events during admission: recurrent angina in 23 cases (28%); heart failure in 5 (6%); exitus in 3 (4%); myocardial infarction in 1 (1%). The cut-off point for troponin I that best predicted events was 0.1 ng/ml. Patients with troponin I > 0.1 (34 patients, 42%) experienced more events [47 vs. 19%; OR = 3.8 (1.4-10.4); p = 0.01] and had higher rates of recurrent angina (42 vs. 19%), heart failure (12 vs. 2%) and exitus (9 vs 0%). Patients with ECG changes and troponin I > 0.1 showed a significantly higher percentage of events (63%) than those with ECG changes alone (23%) or troponin I > 0.1 alone (15%) or those without ECG changes and troponin I < 0.1 (17%) (p < 0.0001).

CONCLUSIONS

Troponin I elevation is useful for predicting in-hospital risk for unstable angina patients admitted to a community hospital. A low cut-off value (0.1 ng/ml) predicts events. The association of ECG changes and high troponin I identifies a population at very high risk; however, the absence of both variables in patients with a diagnosis of unstable angina does not preclude the development of events.

Для цитирования: Bodí Vicente V, Sanchis Juan, Llácer Angel, Graells María L, Llorca Lourdes, Chorro Francisco J, Insa Luis D, Navarro Alejandro, Plancha Eva, Cortés Francisco J, Ponce De León Juan C, Valls Amparo. [Is troponin I useful for predicting in-hospital risk for unstable angina patients in a community hospital? Results of a prospective study].. Revista espanola de cardiologia. 2002. DOI: 10.1016/s0300-8932(02)76568-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.