MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.4c01473

Медицинская библиотека · ACS sensors · 2024

Ultrasensitive Detection of Dimethylamine Gas for Early Diagnosis of Parkinson's Disease Using CeO2-Coated Ti3C2Tx MXene/Carbon Nanofibers.

Wu Haibo, Li Xueguo, Fu Guohui, Xu Pengfei, Fan Chonggui, Shen Lei, Yang Gang, Wen Changming, Liu Wei

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Parkinson's disease is a prevalent neurological disorder, with dimethylamine (DMA) recognized as a crucial breath biomarker, particularly at the parts per billion (ppb) level. Detecting DMA gas at this level, especially at room temperature and high humidity, remains a formidable challenge. This study presents an ultrasensitive chemiresistor DMA gas sensor, leveraging the CeO2-coated Ti3C2Tx MXene/carbon nanofiber (CeO2/MXene/C NFs) heterostructure to enhance dimethylamine sensing. The high conductivity of MXene, combined with C-Ti-O bonds and a sp2 hybridized hexagonal carbon structure, increases surface active sites. The presence of Ce3+ promotes the formation of surface-active oxygen species, while the MXene-CeO2 heterojunction broadens the electron depletion layer. Theoretical calculations reveal that the highest adsorption energy for DMA gas is at the Ce top site, explaining the sensor's satisfactory sensitivity, rapid response and recovery process, low detection limit (5 ppb), and high selectivity at room temperature. The Ce3+/Ce4+ dynamic self-refresh mechanism, involving surface hydroxyl elimination, enhances the sensor's performance under high-humid conditions. Clinical breath tests demonstrate the sensor's ability to distinguish between healthy individuals and Parkinson's disease patients, paving the way for developing next-generation sensors for early diagnosis of neurological disorders.

Для цитирования: Wu Haibo, Li Xueguo, Fu Guohui, Xu Pengfei, Fan Chonggui, Shen Lei, Yang Gang, Wen Changming, Liu Wei. Ultrasensitive Detection of Dimethylamine Gas for Early Diagnosis of Parkinson's Disease Using CeO2-Coated Ti3C2Tx MXene/Carbon Nanofibers.. ACS sensors. 2024. DOI: 10.1021/acssensors.4c01473.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.