MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.12809

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2014

Quantification of mitral regurgitation by real time three-dimensional color Doppler flow echocardiography pre- and post-percutaneous mitral valve repair.

Gruner Christiane, Herzog Bernhard, Bettex Dominique, Felix Christian, Datta Saurabh, Greutmann Matthias, Gaemperli Oliver, Müggler Simon A, Tanner Felix C, Gruenenfelder Juerg, Corti Roberto, Biaggi Patric

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Echocardiographic quantification of mitral regurgitation (MR) can be challenging if the valve geometry is significantly altered. Our aim was to compare the quantification of MR by the recently developed real time three-dimensional (3D) volume color flow Doppler (RT-VCFD) method to the conventional two-dimensional (2D) echocardiographic methods during the MitraClip procedure.

METHODS

Twenty-seven patients (mean age 76 ± 8 years, 56% male) were prospectively enrolled and severity of MR was assessed before and after the MitraClip procedure in the operating room by 3 different methods: (1) by integrative visual approach by transesophageal echocardiography, (2) by transthoracic 2D pulsed-wave Doppler-based calculation of aortic stroke volumes (SV) and mitral inflow allowing calculation of regurgitant volume, and (3) by transthoracic 3D RT-VCFD-based calculation of regurgitant volume.

RESULTS

We found moderate agreement between the integrative visual approach and the 3D RT-VCFD method for assessment of MR severity before (κ = 0.4, P < 0.05) and after MitraClip (κ = 0.5, P < 0.05). Relevant MR (3+ and 4+) was detected by visual approach in 27/27 and by 3D-VCFD method in 24/27 patients before and in 1 patient by both methods after the MitraClip procedure. In contrast, MR quantification by 2D SV method did not agree with the integrative visual approach or with the 3D RT-VCFD method.

CONCLUSIONS

Quantification of MR before and after percutaneous MV repair by 3D RT-VCFD is comparable to the integrative visual assessment and more reliable than the 2D SV method in this small study population. Further automation of 3D RT-VCFD is needed to improve the accuracy of peri-interventional MR quantification.

Для цитирования: Gruner Christiane, Herzog Bernhard, Bettex Dominique, Felix Christian, Datta Saurabh, Greutmann Matthias, Gaemperli Oliver, Müggler Simon A, Tanner Felix C, Gruenenfelder Juerg, Corti Roberto, Biaggi Patric. Quantification of mitral regurgitation by real time three-dimensional color Doppler flow echocardiography pre- and post-percutaneous mitral valve repair.. Echocardiography (Mount Kisco, N.Y.). 2014. DOI: 10.1111/echo.12809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.