Pre-Operative SARS CoV-2 Rapid Antigen Test and Reverse Transcription Polymerase Chain Reaction: A conundrum in surgical decision making.
Аннотация
PURPOSE: Since the eye is in close proximity to the oro-nasal cavity, transmission of SARS CoV-2 is higher during ophthalmic surgical procedures, it is vital to ensure the safety of the healthcare team by pre-operative Rapid Antigen Test (RAT) and real-time Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) for SARS CoV-2 viral RNA of all patients planned for elective or emergency surgery. Hence, understanding the profile of pre-operative RAT and real-time RT-PCR among patients planned for various ophthalmic procedures, will help us make better decisions for future guidelines, for optimal planning of ophthalmic elective or emergency surgeries, keeping in mind the current scenario.
METHODS
This is a prospective descriptive study conducted on patients planned for elective or emergency ophthalmic surgeries, who had no COVID-19-related symptoms pre-operatively and were subjected to preoperative RAT and real-time RT-PCR of nasopharyngeal and throat swabs for SARS CoV-2 viral RNA. Data was compiled and statistically analysed.
RESULTS
204 patients underwent pre-operative RAT and RT-PCR testing; of which, 85 were females and 119 were males. Mean age of the study population was 51.44 ± 16.501 years. Among the 204, 2 tested positive for SARS CoV-2 with Rapid Antigen testing as well as RT-PCR and 10 patients tested positive via RT-PCR after a negative RAT result of the same sample.
CONCLUSION
Pre-operative testing for COVID-19 disease is indispensable as there is a high chance of transmission from patient to healthcare workers. RAT has the advantage of quick results and may play a role in case of emergency procedures. However, it is prudent to perform the more sensitive real-time RT-PCR before any elective, non-emergency procedures or surgeries to avoid any undue risk to the healthcare team.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.