MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14992027.2023.2205009

Медицинская библиотека · International journal of audiology · 2023

Validity and reliability of integrated pressure level real-ear-to-coupler difference measurements.

Urichuk Matthew, Purcell David, Scollie Susan

СтатьяВалидационное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

(1) To validate the measurement of foam-tip real-ear-to-coupler differences (wRECD) using an integrated pressure level (IPL) method and (2) to compare the reliability of this method to SPL-based measurement of the wRECD.

DESIGN

SPL-based wRECD and the proposed IPL wRECD measurement were completed bilaterally. Test-retest reliability of IPL wRECD was determined with full re-insertion into the ear canal and compared to published SPL wRECD test-retest data.

STUDY SAMPLE: 22 adults with normal hearing and middle ear status were recruited.

RESULTS

Differences between SPL-based wRECD and IPL wRECD measurements were within 1.51 dB on average below 5000 Hz. At and above 5000 Hz, IPL wRECD exceeded SPL wRECDs by 6.11 dB on average. The average test-retest difference for IPL wRECD across all assessed frequencies was 0.75 dB with the greatest improvements in reliability found below 750 Hz and above 3000 Hz.

CONCLUSIONS

IPL wRECD yielded improved estimates compared to SPL wRECD in high frequencies, where standing-wave interference is present. Independence from standing wave interference resulted in increased wRECD values above 4000 Hz using the IPL measurement paradigm. IPL wRECD is more reliable than SPL wRECD, does not require precise probe-microphone placement, and provides a wider valid wRECD bandwidth than SPL-based measurement.

Для цитирования: Urichuk Matthew, Purcell David, Scollie Susan. Validity and reliability of integrated pressure level real-ear-to-coupler difference measurements.. International journal of audiology. 2023. DOI: 10.1080/14992027.2023.2205009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.