Assessing the Impact of Transcatheter Aortic Valve Implantation on Cardiac Catheterisation: A Multicentric Study.
Аннотация
BACKGROUND
The success rate of coronary angiography (CA) after transcatheter aortic valve implantation (TAVI) is variable. Our aim was to investigate CA difficulty, outcomes, and predictors of difficult CA after TAVI.
METHOD: This was an international multicentric retrospective cohort study that included patients with TAVI and subsequent CA between January 2010 and December 2019. Difficulty with CA was graded as 1 (normal), 2 (partial engagement, complete vessel opacification), 3 (partial engagement, incomplete vessel opacification), and 4 (unsuccessful angiography). Patients were grouped as (a) "easy" (grade 1 for left and right) or (b) "difficult" (grade >1 for either). We compared baseline characteristics and outcomes, and performed multivariate logistic regression for predictors of difficult CA.
RESULTS
Of 96 patients included (mean age 77.4±8.7 years, 48 [50%] male), 88 (92%) had successful CA. Right CA was successful in 80 (83%) patients and left CA in 91 (95%) (p<0.0001). The "difficult" group (n=41 [43%]) had higher Society of Thoracic Surgery (STS) scores (7.6±4.9 vs 5.4±4.0; p=0.022), smaller annulus perimeters (72.4±5.4 mm vs 76.2±9.4 mm; p=0.049), greater use of self-expanding valves (83% vs 18%; p<0.0001), increased valve size (26.8±2.1 mm vs 25.6±3.0 mm; p=0.032), and increased oversizing for area (44.3%±17.4% vs 23.6%±22.0%; p=0.0002) and perimeter (17.5%±8.2% vs 7.1%±10.8%; p<0.0001). There was no difference in outcomes except for increased major bleeding (7.3% vs 0.0%; p=0.042). The strongest predictor for "difficult" CA was self-expanding valves when compared to balloon-expandable valves (adjusted odds ratio [aOR], 15.23; 95% confidence interval [CI], 2.27-102.40). Society of Thoracic Surgery score was borderline predictive (aOR, 1.26; 95% CI, 1.04-1.52).
CONCLUSIONS
Our results show that after TAVI, CA success rate is high, right CA is more difficult than left, self-expanding valves predispose to difficult CA, and STS score weakly predicts difficult CA. This study is hypothesis-generating and more research is required to confirm these findings.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.