BACKGROUND

Nasal irrigations and topical sprays have been demonstrated to have benefit in chronic sinusitis. Increasingly, it is evident that delivery system, patient anatomy, and inflammatory process have significant impacts on irrigant distribution.

METHODS

Intrasinus endoscopy was performed during sinus irrigation of 5 thawed fresh frozen cadavers (10 sides) before and after transnasal dilation of the maxillary, frontal, and sphenoid ostia with a 5-mm balloon.

RESULTS

Guidewire insertion created false passages through maxillary fontanelle on all of 10 attempts; 1 of 10 frontal insertions entered the ostia in a submucosal plane, while all 10 sphenoid attempts were successful without complication (p < 0.0001). Average minimum ostial dimension increased from 1.73 mm to 3.6 mm (p < 0.0001) after dilation. Obtaining an ostial size of 5 mm was associated with significantly improved irrigation penetration relative to a minimum dimension of 4 mm or less (p = 0.019). After balloon dilation of the true ostia, irrigation of the sphenoid increased, irrigations into the frontal sinuses were unchanged, and irrigation into the maxillary sinuses decreased.

CONCLUSION

Guidewire insertion in this study was noted to frequently create a false passage during maxillary sinus ostial dilation. After balloon dilation, irrigant penetration was increased into the sphenoid sinus for heavy and mist irrigators whereas the maxillary sinus had diminished irrigant penetration for heavy and NetiPot irrigators.

Для цитирования: Brenner Pryor S, Abadie Wesley M, Weitzel Erik K, Thomas Roy F, McMains Kevin C. Unexpected consequences of transnasal balloon dilation of the maxillary ostium.. International forum of allergy & rhinology. 2011. DOI: 10.1002/alr.20085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.