Quantification of aluminium release from Finn chambers under different in vitro test conditions of relevance for patch testing.

Hedberg Yolanda S, Wei Zheng, Matura Mihály

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Contact allergy to aluminium (Al) might pose a risk of false-positive readings of patch-test results when testing with Finn chambers.

OBJECTIVES

To quantify the release of Al from empty Al Finn chambers, covered Finn Aqua chambers, and Al Finn chambers containing different baseline patch-test substances.

METHODS

Al Finn chambers of different conditions and with different patch-test substances were tested in artificial sweat and their Al release was analyzed by atomic absorption spectroscopy and inductively coupled plasma sector field mass spectrometry.

RESULTS

The amount of Al released from empty Finn chambers corresponded to a skin dose of 0.03%-0.5% Al chloride hexahydrate applied in plastic chambers. Although most patch-test substances reduced the release of Al from the Finn chambers due to covering the surface, some substances significantly increased the release of Al from the Finn chambers, most notable for Caine mix II 10% pet., Myroxylon pereirae 25% pet., and sodium tetrachloropalladate hydrate 3.0% pet.

CONCLUSIONS

The release of Al from Finn chambers corresponds in some cases to clinically relevant concentrations of Al for Al-sensitized individuals.

Для цитирования: Hedberg Yolanda S, Wei Zheng, Matura Mihály. Quantification of aluminium release from Finn chambers under different in vitro test conditions of relevance for patch testing.. Contact dermatitis. 2020. DOI: 10.1111/cod.13629.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.