m+Medelevator.RU
← Поиск публикаций
The Thoracic and cardiovascular surgeon · 2021

Transcatheter Aortic Valve Replacement for a Degenerated Transcatheter Valve-A Single Center Experience.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Erlebach Magdalena, Ruge Hendrik, Lange Ruediger

Аннотация

BACKGROUND: The transcatheter valve-in-valve treatment (TAV-in-TAV) of degenerated transcatheter aortic valves is becoming more relevant, as the use of transcatheter aortic valve replacement (TAVR) increases. We report our experience with TAV-in-TAV in patients with a degenerated transcatheter heart valve (THV).

METHODS: We retrospectively analyzed prospectively collected data from our designated TAVR database. Intraprocedural and intrahospital outcomes were reported.

RESULTS: Ten patients out of a total of 3,144 TAVR implantations since 2007 presented with a degenerated THV, among those six with an Edwards Sapien XT (Edwards Lifesciences, Irvine, California, United States) valve, treated with a Medtronic Evolut R (Medtronic, Dublin, Ireland) valve. Four patients had severe stenosis, one pure insufficiency, and five combined stenosis and insufficiency. Average time between initial implantation and re-intervention was 6.8 ± 1.3 years. The mean preoperative maximum and mean gradients were 54.2 ± 14.8 mm Hg and 31.6 ± 9.9 mm Hg, respectively. Nine patients underwent transfemoral and one patient underwent transaortic TAV-in-TAV. Mean procedural time was 86.2 ± 51.5 minutes. Post-implantation, the maximum and mean gradients decreased to 18 ± 6.9 mm Hg and 8.4 ± 3.2 mm Hg (16 ± 8 mm Hg and 6.4 ± 1.7 mm Hg in the Evolut-in-Sapien subgroup), respectively. The valve area increased from 0.98 ± 0.28 mm Hg to 1.72 ± 0.32 mm Hg (0.8 ± 0.07 mm Hg to 1.9 ± 0.16 mm Hg in the Evolut-in-Sapien subgroup). Two patients experienced a vascular complication. No further Valve Academic Research Consortium-2 criteria complications occurred during hospitalization.

CONCLUSION: TAV-in-TAV resulted in low procedural and peri-procedural complication rates. In particular, the usage of a supra-annular valve resulted in excellent hemodynamic results. Larger studies are required to validate this observational data and to establish a protocol for this procedure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты