Semiautomatic Assessment of the Terminal Ileum and Colon in Patients with Crohn Disease Using MRI (the VIGOR++ Project).

Puylaert Carl A J, Schüffler Peter J, Naziroglu Robiel E, Tielbeek Jeroen A W, Li Zhang, Makanyanga Jesica C, Tutein Nolthenius Charlotte J, Nio C Yung, Pendsé Douglas A, Menys Alex, Ponsioen Cyriel Y, Atkinson David, Forbes Alastair, Buhmann Joachim M, Fuchs Thomas J, Hatzakis Haralambos, van Vliet Lucas J, Stoker Jaap, Taylor Stuart A, Vos Frans M

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The objective of this study was to develop and validate a predictive magnetic resonance imaging (MRI) activity score for ileocolonic Crohn disease activity based on both subjective and semiautomatic MRI features.

MATERIALS AND

METHODS

An MRI activity score (the "virtual gastrointestinal tract [VIGOR]" score) was developed from 27 validated magnetic resonance enterography datasets, including subjective radiologist observation of mural T2 signal and semiautomatic measurements of bowel wall thickness, excess volume, and dynamic contrast enhancement (initial slope of increase). A second subjective score was developed based on only radiologist observations. For validation, two observers applied both scores and three existing scores to a prospective dataset of 106 patients (59 women, median age 33) with known Crohn disease, using the endoscopic Crohn's Disease Endoscopic Index of Severity (CDEIS) as a reference standard.

RESULTS

The VIGOR score (17.1 × initial slope of increase + 0.2 × excess volume + 2.3 × mural T2) and other activity scores all had comparable correlation to the CDEIS scores (observer 1: r = 0.58 and 0.59, and observer 2: r = 0.34-0.40 and 0.43-0.51, respectively). The VIGOR score, however, improved interobserver agreement compared to the other activity scores (intraclass correlation coefficient = 0.81 vs 0.44-0.59). A diagnostic accuracy of 80%-81% was seen for the VIGOR score, similar to the other scores.

CONCLUSIONS

The VIGOR score achieves comparable accuracy to conventional MRI activity scores, but with significantly improved reproducibility, favoring its use for disease monitoring and therapy evaluation.

Для цитирования: Puylaert Carl A J, Schüffler Peter J, Naziroglu Robiel E, Tielbeek Jeroen A W, Li Zhang, Makanyanga Jesica C, Tutein Nolthenius Charlotte J, Nio C Yung, Pendsé Douglas A, Menys Alex, Ponsioen Cyriel Y, Atkinson David, Forbes Alastair, Buhmann Joachim M, Fuchs Thomas J, Hatzakis Haralambos, van Vliet Lucas J, Stoker Jaap, Taylor Stuart A, Vos Frans M. Semiautomatic Assessment of the Terminal Ileum and Colon in Patients with Crohn Disease Using MRI (the VIGOR++ Project).. Academic radiology. 2018. DOI: 10.1016/j.acra.2017.12.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.