MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5812/aapm.32299

Медицинская библиотека · Anesthesiology and pain medicine · 2015

Comparison of Tracheal Intubation Using the Storz's C-Mac D-blade(TM) Video-Laryngoscope Aided by Truflex(TM) Articulating Stylet and the Portex(TM) Intubating Stylet.

Al-Qasmi Aida, Al-Alawi Waffa, Malik Azharuddin Mohammed, Manzoor Khan Rashid, Kaul Naresh

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tracheal intubation using Storz's C-Mac D-blade(TM) videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade.

OBJECTIVES

In this study, we hypothesized that Truflex(TM) articulating stylet with its ability to dynamically tailor the ETT shape to patients' oropharyngeal anatomy would be better suited to the D-blade angulation and ease tracheal intubation compared to Portex(TM) intubation stylet.

PATIENTS AND

METHODS

Following approval by the Ethical Issues Committee and informed consent, 218 ASA I and II patients of either sex were enrolled in this interventional, single-blind, randomized controlled trial. Tracheal intubation was performed following a uniform general anesthetic technique using the Storz's C-Mac D-blade(TM) videolaryngoscope aided by either Truflex(TM) articulating stylet or the Portex(TM) intubation stylet by an experienced anesthesiologist. The outcome measures included success or failure to intubate in the first attempt, total intubation time, hemodynamic disturbances, trauma if any and user satisfaction.

RESULTS

The number of patients in whom intubation was successful in the first attempt was significantly higher by using Truflex™ articulating stylet (99.1%) compared to Portex(TM) intubation stylet (90.0%; P-Value = 0.003). User satisfaction grade was significantly better while using Truflex(TM) articulating stylet (8.5 ± 0.88) compared to the Portex(TM) intubation stylet (8.23 ± 0.99; P-Value = 0.035). We did not observe any significant difference in total intubation time, hemodynamic disturbances or trauma.

CONCLUSIONS

Storz's C-Mac D-blade(TM) videolaryngoscope provides grade I Cormack and Lehane's glottic view in 99.1% patients. First attempt successful tracheal intubation and user satisfaction significantly improved by Truflex(TM) articulating stylet compared to the Portex(TM) intubation stylet.

Для цитирования: Al-Qasmi Aida, Al-Alawi Waffa, Malik Azharuddin Mohammed, Manzoor Khan Rashid, Kaul Naresh. Comparison of Tracheal Intubation Using the Storz's C-Mac D-blade(TM) Video-Laryngoscope Aided by Truflex(TM) Articulating Stylet and the Portex(TM) Intubating Stylet.. Anesthesiology and pain medicine. 2015. DOI: 10.5812/aapm.32299.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.