MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0310057x9502300509

Медицинская библиотека · Anaesthesia and intensive care · 1995

"Blind" placement of plastic left double-lumen tubes.

Brodsky J B, Macario A, Cannon W B, Mark J B

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A prospective analysis of placement of left-sided plastic double-lumen tubes in 100 patients is presented. Intubation of the left bronchus was successfully accomplished using only auscultation and clinical signs ("blind" placement) in 91 patients. Double-lumen tubes were positioned in less than five minutes in 84 patients. The most common problem encountered (30%) was initial intubation of the right main bronchus. Seven of these patients required bronchoscopic assistance to guide the tube into the left bronchus. There were four minor intraoperative complications due to DLT malposition that were recognized and corrected by withdrawing the tube slightly back in the bronchus. The plastic double-lumen tubes functioned properly during the procedure in all 100 patients.

Для цитирования: Brodsky J B, Macario A, Cannon W B, Mark J B. "Blind" placement of plastic left double-lumen tubes.. Anaesthesia and intensive care. 1995. DOI: 10.1177/0310057x9502300509.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.