MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/hrt.79.6.605

Медицинская библиотека · Heart (British Cardiac Society) · 1998

Minimally invasive aortic valve replacement through a transverse sternotomy: a word of caution.

Bridgewater B, Steyn R S, Ray S, Hooper T

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare aortic valve replacement (AVR) using a minimally invasive approach through a transverse sternotomy with the established approach of median sternotomy.

DESIGN

Retrospective, case-control study.

PATIENTS: Fourteen high risk patients (median age 78, Parsonnet score of 18%) who underwent AVR performed through a minimally invasive transverse sternotomy were compared with a historical group of patients matched for age, sex, and Parsonnet score who underwent AVR performed through a median sternotomy by the same surgeon.

OUTCOME MEASURES: Cross clamp time, total bypass time, intensive care stay, postoperative in-hospital stay, morbidity, and mortality.

RESULTS

There were two deaths in the minimally invasive group and none in the control group (NS). The cross clamp and total bypass times were longer in the minimally invasive group (67 and 92 minutes v 46 and 66 minutes, p < 0.001). There was a higher incidence of re-exploration for bleeding (14% v 0%) and paravalvar leaks (21% v 0%) in the minimally invasive group but these differences were not significant. The minimally invasive group had a longer postoperative in-hospital stay (p = 0.025). The incidence of mortality or major morbidity was 43% (six of 14) in the minimally invasive group and 7% (one of 14) in the matched pairs (p = 0.013).

CONCLUSIONS

AVR can be performed through a transverse sternotomy but the operation takes longer and there is an unacceptably high incidence of morbidity and mortality.

Для цитирования: Bridgewater B, Steyn R S, Ray S, Hooper T. Minimally invasive aortic valve replacement through a transverse sternotomy: a word of caution.. Heart (British Cardiac Society). 1998. DOI: 10.1136/hrt.79.6.605.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.