Non-fluoroscopic catheter ablation of arrhythmias with origin at the summit of the left ventricle.
Аннотация
BACKGROUND
Catheter ablation of ventricular arrhythmias (VAs) arising from the left ventricular Summit (LVS) is challenging and requires high-dose fluoroscopy to limit vascular damage of the coronary arteries. Ionizing radiation can increase the incidence of malignancies to both patient and operator. This study describes outcomes of catheter ablation of LVS VAs using intracardiac echo-facilitated 3D electroanatomical mapping (ICE-3D) to avoid fluoroscopy.
METHODS
Twenty-six patients (47 ± 17 years old; 52% males; median ejection fraction 55 ± 13%) with premature ventricular contractions or ventricular tachycardia underwent catheter ablation. VAs were localized using ICE-3D with arrhythmia foci being mapped at the LVS. Focal ablation was performed using a 3.5-mm open-irrigated, contact force sensing radiofrequency catheter.
RESULTS
Acute success and recurrence rates were 84% and 24%, respectively. Holter burden was significantly reduced (24 ± 15% to 1.5 ± 2%; P = 0.01) after ablation. The use of zero fluoroscopy was achieved in 100% of cases. No major complications were observed.
CONCLUSIONS
Zero fluoroscopy catheter ablation of LVS VAs using ICE-3D mapping is feasible and effective.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.